By Vaibhav K. Arghode, Yogendra Joshi

The short talk about essentially features of ventilation administration in raised flooring info facilities. first of all, cooling air supply via perforated tiles should be tested and effect of the tile geometry on movement box improvement and sizzling air entrainment above perforated tiles could be mentioned. Secondly, using chilly aisle containment to bodily separate cold and hot areas, and reduce cold and warm air blending may be offered. either experimental investigations and computational efforts are mentioned and improvement of computational fluid dynamics (CFD) established types for simulating ventilation in information facilities is incorporated. furthermore, metrology instruments for facility scale air speed and temperature dimension, and ventilation cost size via perforated ground tiles and server racks are tested and the authors current thermodynamics-based versions to gauge the effectiveness and significance of ventilation administration schemes in facts centers.

Show description

Read or Download Air Flow Management in Raised Floor Data Centers PDF

Best thermodynamics books

Thermodynamics and the Destruction of Resources

This booklet is a distinct, multidisciplinary, attempt to use rigorous thermodynamics basics, a disciplined scholarly technique, to difficulties of sustainability, strength, and source makes use of. utilising thermodynamic pondering to difficulties of sustainable habit is an important virtue in bringing order to ailing outlined questions with an excellent number of proposed recommendations, a few of that are extra harmful than the unique challenge.

Advances in Thermal Design of Heat Exchangers: A Numerical Approach: Direct-Sizing, Step-Wise Rating, and Transients

Content material: bankruptcy 1 type (pages 1–18): bankruptcy 2 basics (pages 19–57): bankruptcy three regular? kingdom Temperature Profiles (pages 59–97): bankruptcy four Direct? Sizing of Plate? Fin Exchangers (pages 99–142): bankruptcy five Direct? Sizing of Helical? Tube Exchangers (pages 143–176): bankruptcy 6 Direct? Sizing of Bayonet?

Additional resources for Air Flow Management in Raised Floor Data Centers

Example text

Note that reduction in aisle width may not be practically feasible in some cases, and reducing the tile width by blocking a portion of the standard tile, as done here, can be used to improve air delivery. 2 Computational Fluid Dynamics (CFD) Modeling Air flow modeling is extensively used in designing and thermally managing data centers. From the previous section, it can be recognized that the tile’s geometrical features have significant effect on the downstream flow characteristics. Hence for improving predictive capability of the numerical models to simulate air flow in data centers, it is important to incorporate these effects.

The tool air flow resistance is compensated by measuring the tile air flow rate at two different resistance levels, from which the actual tile air flow rate is deduced. Note that the tool manufacturers have not shared the operating formulation to obtain the actual tile air flow rate. Here, we present the possible air flow rate measurement principle. The tool is designed to measure the air flow rate through passive tiles. However, we also discuss its applicability for active tiles, with integrated fans.

48 (Breen et al. 40 (Breen et al. 88 (Breen et al. 90 (Breen et al. 982 (Samadiani et al. 60 (Breen et al. 12 (Breen et al. 30 (Breen et al. 04 (Breen et al. 32 (Breen et al. 2012) (Tcon-wat-out − Tcon-wat-in) (°C) However, as observed from the model above, movement of larger quantities of air would increase the energy consumption and may even offset the energy savings at the chiller plant, thus an optimal solution needs to be sought for energy efficient operation. This example illustrates the importance of effective air flow management, which will directly impact the energy consumption in a data center.